Zometric Logo
CAPA & 8D · VDA 8D, CQI-20 & IATF 16949

How do you know a closed problem stays closed?

One 8D case for every complaint, audit finding and internal problem. Each step is gated, containment stays until the fix is proven, and an effectiveness review follows every closure.

  • Gates on every discipline
  • Containment lifted only after proof
  • Lessons flagged on the PFMEA

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Free trial request

Try Zometric on your own process.

Tell us a little about your plant. Our team will contact you to set up a free trial around the modules you need.

Prefer to talk now?

CAPA-000231 · Generic 8D · Full 8DCustomer complaint
Seal leak at end-of-line test, pump housing
D0D1D2D3D4D5D6D7D8
D4 Find root causes · due 17 Mar 09:00
D3 ContainmentStays until a proof passes
C1Finished goods · Active1,240 checked · 3 NOK
C2At customer · Active600 checked · 0 NOK
D4 Root causes
OC-1Chamfer below drawing minimum pinches the O-ringTechnical · OccurrenceVerified
ND-1Leak test limit set above the specificationTechnical · Non-detectionMost likely
SY-1Tool change released without a chamfer checkSystemicPotential
Warning · OC-1: “Was it in the FMEA?” not answered

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Free trial request

Try Zometric on your own process.

Tell us a little about your plant. Our team will contact you to set up a free trial around the modules you need.

Prefer to talk now?

The method

What is CAPA and the 8D method?

CAPA (corrective and preventive action) removes the cause of a problem that has happened so it cannot happen again, and carries the lesson to the products, processes and sites where it could happen next. 8D (Eight Disciplines) is the team method automotive customers expect for it: IATF 16949 clause 10.2.3 asks for containment, root-cause analysis, systemic corrective action, verified effectiveness and an updated PFMEA and Control Plan.

Zometric runs nine steps, D0 to D8: intake and triage, team, problem description, containment, root causes, selecting and testing actions, implementing and proving them, preventing recurrence, and closure with team recognition. D0 decides between a full 8D and a short form. The same steps can be shown in the VDA 8D or AIAG CQI-20 wording.

A verified root cause must explain the facts and, where possible, switch the problem on and off. Causes are split into why the defect occurred and why it was not detected, and into technical and systemic causes, because a fix that only covers the part leaves the process that let it through unchanged.

Why teams switch

Problems Zometric CAPA & 8D removes

Six problems quality teams describe in their own words — and what changes when the 8D is a gated case instead of a form.

Root cause

Our 8Ds blame the operator, and the problem comes back.

With Zometric

D4 cannot be completed without a verified cause of the occurrence and, in a full 8D, a verified systemic cause — each backed by evidence. The format can also require the non-detection cause.

Root-cause classes and verification
Containment

Nobody knows when the sorting can stop.

With Zometric

Each containment action records its location, lots, quantities checked and rejected, and a clean point. It can be removed only after a proof after implementation has passed; an override needs the sponsor or a quality manager and a written reason.

Prove before you remove
Customer formats

Every customer wants the 8D on their own form.

With Zometric

The team works one case. The format sets the step names, required root-cause classes, sign-offs and report layout, and the customer's own 8D workbook is filled from an issued report version.

Customer formats and workbooks
Deadlines

We miss the 24-hour containment deadline without noticing.

With Zometric

Every step gets a due date counted from when the problem was reported. The team leader is reminded, and a step more than three days overdue is escalated to the quality managers.

Step due dates and escalation
Prevention

The PFMEA never hears about the complaint.

With Zometric

D7 needs a decision on the PFMEA and the Control Plan. A planned or done decision raises a review flag on the document, and lessons learned, work instructions and similar products become tracked actions.

D7 review flags
Effectiveness

We closed it, and months later it was back.

With Zometric

Closure schedules an effectiveness review. Repeat complaints since closure appear as recurrence signals, and a failed review reopens the case or starts a linked repeat CAPA.

Effectiveness review
How it works

How an 8D runs in Zometric

Each discipline has its own checks: an open error blocks the step, and a next-step card says what is missing.

  1. D0 · Intake and triage

    Open and triage the case

    A case opens from a customer or supplier complaint, an audit finding, a layered-audit nonconformance or an internal source. Three triage questions suggest a full 8D or a short form; safety, regulatory and critical problems always get a full 8D.

  2. D1–D2 · Team and problem description

    Form the team and describe the problem

    Name a sponsor and a team leader, add members, customer or supplier representatives. Describe the problem as requirement against actual, with 5W2H, IS / IS NOT, the error pattern and checks on similar parts, lines and sites.

  3. D3 · Containment

    Contain it

    Record containment by location — supplier, work in progress, finished goods, in transit, at the customer — with lots, quantities checked and rejected, and dispositions. Use as is and repair need the customer's authorization; suspect product already shipped needs customer notification.

  4. D4 · Root causes

    Find and verify the root causes

    Work with 5-Why, Ishikawa, IS / IS NOT, Pareto, fault tree, decision matrix, multi-vari or a cause-and-effect matrix, and promote the likely cause to a root cause. The PFMEA chains and Control Plan rows of the project sit beside it, so the team can answer “was it in the FMEA?”.

  5. D5–D6 · Actions and proof

    Select, test and prove the actions

    Link corrective and systemic actions to the causes they remove. Fix the acceptance criteria before any result is recorded, test before implementation, then prove after it — optionally against live SPC or inspection data, before and after the change.

  6. D7 · Prevent recurrence

    Carry the lesson

    Decide each prevention target: PFMEA, DFMEA, Control Plan, process flow, work instructions, similar products and processes, other sites, lessons learned or an LPA question. Each decision is done, planned with an owner and date, or not applicable with a reason.

  7. D8 · Closure and recognition

    Close, sign and review

    Submit a closure summary for sign-off by the team leader and sponsor, plus the customer when the complaint requires it; approvals can be signed electronically. Closure schedules the effectiveness review, 90 days later by default.

Want to see CAPA & 8D on your own process?
A 30-minute call covers your products, your customers' requirements and the tools you use today.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

What it does

CAPA & 8D Problem Solving — what you actually get.

Each capability is tied to a decision your team is already trying to make.

8D From D0 to D8, With Gates

Each discipline has its own checks, and an open error blocks the step. A next-step card tells the team leader what is needed to move on — so an 8D cannot be closed without a verified root cause backed by evidence.

VDA 8D, CQI-20 and Your Customer's Format

Work the problem once and report it in the format the customer demands. Formats define the steps, labels and report layout — including customer workbooks — without changing how the team solves the problem.

Containment With Lots & Clean Point

Containment actions by location — your plant, in transit, the customer's warehouse — with the affected lots, quantities sorted and dispositions. The clean point is recorded, and containment can only be lifted once the permanent fix is proven, unless the sponsor or a quality manager overrides it with a written reason.

Root Cause: Occurrence and Non-Detection

5-Why, Ishikawa, Pareto, Is / Is-Not, fault tree and decision matrix, each on the case record. Root causes are separated into why the defect occurred and why it escaped, with the related PFMEA and Control Plan context beside them.

D7 Prevention Into PFMEA & Control Plan

Prevention is a decision made against real documents. Choose the PFMEA, Control Plan or process flow the lesson applies to and a review flag is raised on it — the loop from a field failure back to the risk analysis is closed in the system, not in a meeting.

Effectiveness You Have to Prove

An effectiveness review is scheduled at closure. If the problem has come back, the case reopens. A repeat complaint on a closed CAPA raises a flag on it automatically.

Evidence, Sign-Offs & Report Versions

Photos and files on every step, e-signed sign-offs, and numbered report versions — initial, interim and final — frozen as issued. A management-review pack exports the whole CAPA picture to Excel.

Learns From Your Past Cases

Similar past cases, proven root causes and actions that worked are suggested from your own CAPAs and FMEAs, each with a citation. No external LLM is used in this module, and the engineer decides what to accept.

In numbers

When each 8D step falls due

Step due dates count from the moment the problem was reported, not from when someone opened the case. These are the defaults of the VDA 8D, CQI-20 and Generic 8D formats; each can be changed in a duplicated format, and complaint and audit deadlines replace them.

24
Hours to contain (D3)
15
Days to root cause and plan (D4–D5)
60
Days to implement and close (D6–D8)
Problem reported 2 Mar 2026, 09:00 — default due dates, Generic 8D format
StepDue afterDue on
D0 Prepare and reactDue after24 hDue on3 Mar 09:00
D1 TeamDue after24 hDue on3 Mar 09:00
D2 Describe the problemDue after5 daysDue on7 Mar 09:00
D3 ContainDue after24 hDue on3 Mar 09:00
D4 Find root causesDue after15 daysDue on17 Mar 09:00
D5 Choose and test actionsDue after15 daysDue on17 Mar 09:00
D6–D8 Implement, prevent, closeDue after60 daysDue on1 May 09:00
If D4 is still open on 21 March — more than three days overdue — the reminder is escalated to the quality managers. A complaint's own deadlines replace D3, D4 and D8, and an audit finding uses its response times. Closed on 1 May, the case is due for its effectiveness review on 30 July.
Connected modules

How CAPA & 8D connects to the rest of Zometric

Other modules open cases through CAPA and hear back when they change, so nothing is retyped between them.

Who uses it

Who works in it

Team leader

Runs the case: triage, the steps, the closure request and the effectiveness review. Receives the reminders for steps due soon or overdue.

Sponsor / champion

Signs the closure with the team leader, and can override a containment removal with a written reason.

Team members

Work the disciplines — problem description, containment, analyses, root causes and actions. Triage and closure stay with the team leader and sponsor.

Quality managers

Manage any case, receive the escalations of overdue steps, sign quality-manager sign-offs and can override a containment removal.

Source owners

Complaint coordinators, audit programme managers and LPA process owners manage the CAPAs opened from their complaints, findings and layered audits.

Suppliers

Answer containment, root causes, actions and implementation for their 8D through the Supplier Portal.

Comparison

Zometric CAPA & 8D vs a spreadsheet or Word 8D template

Zometric CAPA & 8D vs a spreadsheet or Word 8D template
Zometric CAPA & 8D vs a spreadsheet or Word 8D templateSpreadsheet or Word templateZometric CAPA & 8D
Step gatesAny box can be left empty or vague52 CAPA rules; open errors block the step and the closure
Root causesOne free-text boxTechnical and systemic causes of occurrence and non-detection, each verified with evidence
Containment exitStopped when it feels safeRemoved only after a passed proof, or overridden with a reason
Due datesTyped by hand, rarely chasedCounted from the report date, with reminders and escalation
PFMEA and Control Plan"Updated" written in D7A D7 decision is required and raises a review flag on the document
Customer formatsA different file for each customerOne case; VDA 8D, CQI-20 or customer formats and workbooks
EffectivenessRarely checked after closureReview scheduled at closure; a failed review reopens the case
Versions and sign-off"8D_final_v2" sent by e-mailNumbered report versions frozen as issued, with electronic signature
Want to see CAPA & 8D on your own process?
A 30-minute call covers your products, your customers' requirements and the tools you use today.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Standards & Compliance

Built for the standards your regulators and customers already require.

  • 8D
  • VDA 8D
  • CQI-20
  • IATF 16949
  • ISO 9001
Integrations

Data in and out

8D report

The 8D report in VDA 8D, CQI-20 or generic layout on screen, with a print layout for PDF and an Excel workbook with one sheet per discipline.

Customer 8D workbook

Upload the customer's blank 8D workbook, map its cells once, and fill it from any issued report version.

Register and management review

Export the CAPA register with its KPIs, and a management-review pack with trend, sources, cause Pareto, open and closed cases and effectiveness, to Excel.

Catalogue imports

Load customer cause catalogues, format texts and assessment criteria from Excel or CSV.

REST API and webhooks

Cases, steps, team, containment, root causes and sign-offs are available through the REST API, with a webhook when a case changes status.

FAQ

CAPA & 8D: frequently asked questions

Straight answers to the questions teams ask before a demo.

What is the difference between CAPA and 8D?

CAPA (corrective and preventive action) is the requirement: remove the cause of a problem so it does not come back, and prevent it elsewhere. 8D is a structured team method for doing it, in eight disciplines from team to closure. Zometric runs every CAPA as an 8D case with nine steps, D0 to D8, where D0 decides between a full 8D and a short form.

Which 8D formats does Zometric support?

Zometric ships three formats: VDA 8D, CQI-20 problem solving and a Generic 8D. A format sets the step names, required root-cause classes, verification level, sign-offs, due dates and report layout. Formats can be duplicated and adjusted for a customer, and a customer's own 8D workbook can be filled from an issued report version.

When can a short-form 8D be used instead of a full 8D?

At triage, three questions suggest the approach: whether the cause is known, whether the problem description is complete, and whether the problem exceeds one person. Safety, regulatory and critical problems always get a full 8D, and so do customer complaints unless the format allows a short form. A short form that turns out bigger can be escalated to a full 8D without losing data.

How are 8D due dates set?

Due dates count from when the problem was reported. The default is 24 hours for containment, 15 days for root causes and the action plan, and 60 days for implementation, prevention and closure. A complaint's deadlines or an audit finding's response times replace them, and a step more than three days overdue is escalated to the quality managers.

When can containment be removed?

Only after the corrective actions have a passed proof after implementation. A format can also require the customer's exit approval or a clean period after the clean point. Removing containment earlier needs a sponsor or quality manager and a written reason, which is kept with the record.

How does Zometric verify that a CAPA was effective?

Closure schedules an effectiveness review, 90 days later by default. Repeat complaints since closure appear as recurrence signals, and confirming effectiveness despite them needs a written justification. A failed review reopens the case from the chosen step, or keeps it closed and starts a linked repeat CAPA.

Can suppliers answer an 8D in Zometric?

Yes. Through the Supplier Portal, a supplier answers containment, root causes, corrective actions and implementation from a secure link. Their answers stay proposals: nothing is written into the CAPA until the team accepts them, and accepted root causes start as most likely, not verified.

Does Zometric's AI send our CAPA data to an external AI model?

No. Suggestions for root causes, actions and prevention targets come from a local engine that searches your own past CAPAs and FMEAs, each with a citation. No external LLM is used, and nothing is added to the case until an engineer accepts it.

See CAPA & 8D running on your line.

A 30-minute discovery call. A 2–3 week pilot on real factory data. Then scale at your pace.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Free trial request

Try Zometric on your own process.

Tell us a little about your plant. Our team will contact you to set up a free trial around the modules you need.

Prefer to talk now?

Talk to an engineer