Zometric Logo
QbD · ICH Q8, Q11 and Q14

Can every range you file be traced to the evidence behind it?

Zometric QbD is DoE and experiments management built for pharmaceutical formulation and method development, from the first risk assessment to the tables in the dossier.

  • One record from risk assessment to dossier
  • Regions proven on prediction limits
  • Filing tables generated, not typed

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

See all modules
HPLC assay · Filing table
ParameterFiled asRange
Column temperatureMODR32–38 °C
Mobile-phase pHMODR2.8–3.2
Flow ratePAR0.9–1.1 mL/min
Injection volumeSet-point10 µL
Detection wavelengthFixed254 nm
Change checkCC-2026-031
Column temperature 37 °C (filed 35 °C)Inside the approved MODR
Smallest marginResolution: lower prediction limit 2.2 ≥ 2.0
RouteWithin the PQS
The method

What is Quality by Design (QbD) software?

Quality by Design is the approach ICH Q8(R2), Q11 and Q14 describe for pharmaceutical development: start from the quality the product or method must deliver, use risk assessment to decide which parameters matter, study them with designed experiments, and file a control strategy built on that understanding. Regulators reward understanding a reviewer can follow. Working within an approved design space is not considered a change, and moving within an approved PAR or MODR does not require regulatory notification.

QbD software keeps that evidence chain in one place. In most companies today it is spread across a risk-assessment spreadsheet, a statistics package, notebooks, contour screenshots and hand-built filing tables, so a filed range cannot be traced in one step to the model, runs and risk assessment behind it.

Zometric QbD links each step on one versioned record: the target profile and critical quality attributes, the risk assessment, the experiments, the sealed model, the proven operating region and the filing tables generated from it. Correct a run and everything built on it is flagged for review. It serves analytical development under ICH Q14, drug product under ICH Q8 and drug substance under ICH Q11, with both the traditional and the enhanced approach.

Why teams switch

Problems Zometric QbD removes

Six things development, quality and regulatory teams say about the evidence behind a filing, and what changes with Zometric QbD.

Trust

We re-ran the study because we could not trust the first one.

With Zometric

Every model is sealed with the runs it used and versioned. Correct a run and the models, regions and tables built on it are flagged for review, so the study stays trustworthy instead of being repeated at the cost of analyst time, instrument time and scarce API.

Sealed, versioned models
Ranges

The reviewer asked for ranges; we had a picture.

With Zometric

With five or six parameters a region cannot be drawn. Zometric QbD files it as a table of ranges, each with what limits it, generated from the proven region rather than rebuilt by hand from a contour plot.

Filing tables
Transfer

The method failed at transfer.

With Zometric

One-factor-at-a-time robustness cannot see interactions, and interactions are where methods fail at the receiving site. Factorial and response-surface designs study them, and robustness designs around the set-point can be reused as validation evidence.

Robustness and optimisation designs
Changes

A small change became a regulatory submission.

With Zometric

With approved ranges on record, a proposed operating point is checked against the filed region. Inside it, the change can be managed in the quality system; outside it, the same record opens the regulatory change with the evidence attached.

Lifecycle change check
Audit

The audit question took a week.

With Zometric

Every record and change carries the named user and a server timestamp, nothing is deleted and superseded versions stay reviewable. Who changed what, when and why is on record, not reconstructed from files and drives.

Audit trail
Knowledge

The knowledge left with the scientist.

With Zometric

The rationale for each set-point, from the risk-assessment decision to the model and the boundary that limits it, lives in the study. The next product, team or site starts from that prior knowledge, not a blank sheet.

Linked study record
How it works

How a study moves through Zometric QbD

One evidence chain, from the target profile to a lifecycle change. Any number in a filing table traces back, in one step, to the model, the runs and the risk assessment that produced it.

  1. 1 · Plan

    Start from what quality means

    Declare the profile (analytical, drug product or drug substance), the target profile (ATP or QTPP), the attributes with their acceptance criteria, and the approach for each step. A risk assessment links each parameter to the attributes it can affect and records whether it is studied, controlled or fixed, with the rationale.

  2. 2 · Experiment

    Choose the right design for each question

    Screening (fractional factorial, Plackett–Burman, definitive screening), characterisation (factorial, with split-plot for hard-to-change factors), optimisation (central composite, Box–Behnken, I-optimal), mixture designs with constraints between components, and small robustness designs around the set-point.

  3. 3 · Model

    Fit and seal the model

    Analyse with diagnostics, transformations and prediction intervals. The software refuses to fit what a design cannot support, and each model is sealed with a content hash and the runs it used.

  4. 4 · Region

    Prove the operating region

    Define the design space, MODR or PARs. Each criterion is judged against the prediction limit for an individual future result, the region is proven everywhere rather than checked at the corners, and every boundary says what limits it: a criterion, the edge of what was studied, or prior knowledge.

  5. 5 · Control strategy

    Generate the filing content

    Produce the filing table with Established Conditions, the control-strategy summary per CQA, the CQA rationale, the studies table and the SST justification, each carrying its CTD section.

  6. 6 · Lifecycle

    Check every proposed change

    Enter a new operating point and see whether it is inside the approved region, the smallest margin and what limits it. The check is saved only with a change-control reference, and routes the change within the PQS or to a regulatory submission.

Want to see QbD on your own process?
A 30-minute call covers your products, your customers' requirements and the tools you use today.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

What it does

Quality by Design (QbD) — what you actually get.

Each capability is tied to a decision your team is already trying to make.

Target Profile & Risk Assessment

Declare the ATP or QTPP, the CQAs with their acceptance criteria and the approach per step. The risk assessment links each parameter to the attributes it can affect and keeps each study, control or fix decision with its rationale.

Designs for Pharmaceutical Questions

Screening, factorial with split-plot, central composite, Box–Behnken and I-optimal, mixture designs with constraints between components, and robustness designs around the set-point that can be reused as validation evidence.

Sealed, Versioned Models

Diagnostics, transformations and prediction intervals, with every model sealed by a content hash and the runs it used. Correct a run and everything built on it is flagged for review.

Proven Design Space, MODR & PAR

Each criterion is judged on the prediction limit for a future result, the region is proven everywhere rather than at the corners, and every boundary says what limits it. An unproven region cannot be approved.

Filing Tables & Control Strategy

The filing table with Established Conditions, the control-strategy summary per CQA, the CQA rationale, the studies table and the SST justification, generated from the record with their CTD sections.

Lifecycle Change Check

Check whether a proposed operating point is inside the approved region, with its smallest margin and what limits it. Saved with a change-control reference, and routed within the PQS or to a regulatory submission.

In numbers

A filing table generated from one HPLC method

For an HPLC assay, the risk assessment sent column temperature, mobile-phase pH, flow rate and gradient slope into the experiment, kept injection volume at a set-point and fixed the detection wavelength from prior knowledge. The model and proven region then generate the table regulatory writers need: each parameter's set-point, how it is filed, its range, what limits the range and its proposed reporting category.

2
Parameters in the MODR
1
Proven acceptable range
5
Established Conditions
Illustrative filing table for one HPLC method
ParameterSet-pointFiled asRangeLimited byReporting category
Column temperatureSet-point35 °CFiled asMODRRange32–38 °CLimited byResolutionReporting categoryNotification (moderate)
Mobile-phase pHSet-point3.0Filed asMODRRange2.8–3.2Limited byTailingReporting categoryNotification (moderate)
Flow rateSet-point1.0 mL/minFiled asPARRange0.9–1.1 mL/minLimited byStudied rangeReporting categoryNotification (low)
Injection volumeSet-point10 µLFiled asSet-pointRange—Limited by—Reporting categoryNotification (low)
Detection wavelengthSet-point254 nmFiled asFixedRange—Limited by—Reporting categoryPrior approval
Every parameter here is an Established Condition. Later, a proposed change to a column temperature of 37 °C is checked against this table: it is inside the approved MODR, the smallest margin is resolution, with a lower prediction limit of 2.2 against a criterion of 2.0, and the change can be managed within the PQS under its change-control reference. Values and reporting categories are examples; Regulatory Affairs proposes the categories.
Who uses it

What changes for each team

Formulation and process

Design, model and design space sit in one study and are reused for the next product, instead of designs and reports rebuilt by hand per product.

Analytical development

An MODR with proven ranges and SST limits traced to the model, instead of one-factor-at-a-time robustness and SST limits set by convention.

QC laboratories

Methods arrive with ranges, margins and the evidence behind them, not just set-points with little context.

Regulatory affairs

Design-space and control-strategy tables are generated from the evidence, with their CTD sections, instead of assembled by hand.

Quality assurance

One audit trail with the reason for every change answers data-integrity questions that used to need scattered files.

Manufacturing and transfer

Proposed changes are checked against what was filed in minutes, instead of every adjustment being argued again.

Comparison

Today's tools vs Zometric QbD

Today's tools vs Zometric QbD
Today's tools vs Zometric QbDTodayZometric QbD
Where evidence livesSix tools and several shared drivesOne linked, versioned study
Design spaceA contour screenshotA proven region and a table of ranges
Filing tablesRebuilt by hand for each submissionGenerated, with CTD sections
Audit trailReconstructed from files when askedEvery change on record: who, when, why
Lifecycle changeArgued again from scratchChecked against what was filed
The next productStarts from a blank sheetStarts from your prior knowledge
Want to see QbD on your own process?
A 30-minute call covers your products, your customers' requirements and the tools you use today.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Standards & Compliance

Built for the standards your regulators and customers already require.

  • ICH Q8(R2)
  • ICH Q9(R1)
  • ICH Q10
  • ICH Q11
  • ICH Q12
  • ICH Q14
  • ICH Q2(R2)
Integrations

Data, security and assurance

Whole-study export

Every study exports in full, with data, models and audit trail, in open, human-readable formats. Historical data can be imported selectively, with its source recorded.

Dedicated instance

Each customer runs on its own instance, upgraded on its own schedule, with encryption and documented backup and restore.

Single sign-on and MFA

Sign-in through your identity provider, with multi-factor authentication.

Assurance package per module

Requirements, functional specification, traceability and test evidence for each module, statistical engines tested against reference results on every release, and release notes with an impact assessment for each change.

FAQ

QbD: frequently asked questions

Straight answers to the questions teams ask before a demo.

What is QbD software?

Software that keeps the evidence chain of Quality by Design in one record: the target profile and critical quality attributes, the risk assessment, the designed experiments, the model, the proven operating region and the control strategy filed from it. Zometric QbD does this for analytical development (ICH Q14), drug product (ICH Q8) and drug substance (ICH Q11).

Does it support the traditional approach as well as the enhanced approach?

Yes. The traditional or minimal approach gets robustness designs, PARs from the set-point one factor at a time, and filing tables. The enhanced approach adds risk assessment linked to parameters, screening, optimisation and mixture designs, and proven regions. ICH Q11 allows the traditional approach for some steps and the enhanced approach for others, and the record keeps which is which.

What is the difference between a design space, an MODR and a PAR?

A PAR (proven acceptable range) is a range for one parameter, with the others held constant, that gives acceptable quality (ICH Q8). An MODR (method operable design region) is the combined ranges of two or more method parameters within which the method is fit for purpose (ICH Q14). A design space is the demonstrated combination of inputs and parameters that assures quality (ICH Q8).

Why judge a design space on prediction limits?

A region drawn from mean responses overstates how much of it will pass. Zometric QbD tests each criterion against the prediction limit for an individual future result, and proves the region everywhere inside it, because a curved response can fail inside a box that passes at every corner.

Which filing documents does it generate?

A filing table with set-points, ranges, what limits each range, Established Conditions and proposed reporting categories, plus a control-strategy summary per CQA, a CQA rationale including attributes considered and excluded, a studies table with ranges studied versus proposed, and an SST justification tracing each system-suitability limit to the model. Every export carries its CTD section, such as 3.2.P.2 or 3.2.S.4.

How does it handle a post-approval change?

A proposed operating point is checked against the approved region, with the smallest margin and what limits it. Inside the region the change can be managed in the company's quality system (ICH Q14 §5.2); it is still a change, so the check is saved only with a change-control reference. Outside the region, the same record opens the regulatory change with the evidence attached. Regional implementation of Q12 and Q14 varies, so confirm the position in your markets with Regulatory Affairs.

How does it support data integrity?

Every record and change carries the named user and a server timestamp with time zone, each model is sealed with a content hash and the runs it used, nothing is deleted, superseded versions stay reviewable, and a whole study exports with its audit trail. Development data matters before GMP because it is summarised in the dossier, in 3.2.P.2 and 3.2.S.2.6.

Is training included?

Zometric offers structured courses taught on the software: Core DoE for Pharma, Formulation and Mixture DoE, and Analytical DoE (AQbD). No prior DoE background is assumed, the worked examples are pharmaceutical, and both the traditional and the enhanced approach are covered as ICH describes them.

See QbD running on your line.

A 30-minute discovery call. A 2–3 week pilot on real factory data. Then scale at your pace.

Demo request

Tell us about your factory.

30-minute call, zero obligation. We map the right Zometric modules to your KPIs and priority areas.

Prefer to talk now?

Talk to an engineer