Power and Sample Size for 1-Sample Z
Plans a 1-sample Z-test of one mean when the standard deviation is known, for example from a long, stable control chart history. Enter any two of sample size, difference and power, plus the known standard deviation, and the tool solves for the third using closed-form normal formulas. Outputs a results table with actual power and a power curve. If the standard deviation will be estimated, use 1-Sample t.
Last reviewed
Key takeaway
Power and Sample Size for 1-Sample Z plans a test of one mean against a target when the process standard deviation is known, solving for sample size, power or the smallest detectable difference.
On this page
Purpose
Power and Sample Size for 1-Sample Z plans a test of one mean against a target when the process standard deviation is known, for example from a long, stable control chart history. It answers how many measurements are needed to detect a shift that matters, what power a planned sample gives, or the smallest shift a given sample can detect. Enter any two of sample size, difference and power, and the tool solves for the third. Use it before a 1-sample Z-test; if the standard deviation will be estimated from the sample, use Power and Sample Size for 1-Sample t instead.
Key Capabilities
- Solves for sample size, power or difference: leave blank the one you want.
- Several values at once, e.g. sample sizes “10 20 30”, give one row for each combination.
- Two-sided (Mean ≠ hypothesized mean) or one-sided (Mean < hypothesized mean, Mean > hypothesized mean) alternatives, at the confidence level you choose.
- Closed-form normal calculation, so results are exact for a known standard deviation.
- Power curve of power against sample size for each difference, with the solved points marked.
Statistical Methods
The test statistic is Z = (x̄ − μ₀) / (σ/√n) with σ treated as known, so the calculation uses the standard normal distribution throughout. The significance level is α = 1 − confidence level / 100, the standardised difference is d = difference / σ (the difference being the true mean minus μ₀), and z is z₁₋α/₂ for the two-sided alternative or z₁₋α for a one-sided one.
For a two-sided test, power = Φ(|d|·√n − z) + Φ(−|d|·√n − z); for Mean > hypothesized mean, power = Φ(d·√n − z), and for Mean < hypothesized mean, power = Φ(−d·√n − z), so a one-sided test has power near 0 for a difference on the wrong side. The sample size for a target power is n = ((z + z_β) / d)², where z_β is the normal quantile of the target power; n is rounded up and the power at that whole number is reported as the actual power. The smallest detectable difference for a given n and power is σ·(z + z_β)/√n, reported as a negative difference for the “less than” alternative.
Because σ is not estimated, the Z calculation gives slightly higher power than the t calculation at the same sample size, most noticeably for small samples. Use it only when the standard deviation really is known and stable. With a one-sided alternative, solving for sample size from a difference on the wrong side returns an error message.
Input Fields & Options
Field | Description |
Sample sizes | Space or comma-separated, e.g. “10 20 30”. Leave blank to solve for sample size. |
Differences | Space or comma-separated, e.g. “1 2 3”. The difference from the hypothesized mean you want to detect. Leave blank to solve for difference. |
Power values | Space or comma-separated, e.g. “0.8 0.9”. Leave blank to solve for power. |
Known standard deviation | Required. The population standard deviation, assumed known (not estimated from the sample). |
Confidence level | Default 95 (α = 0.05); 75 to 100. |
Alternative hypothesis | Mean ≠ hypothesized mean (default), Mean < hypothesized mean or Mean > hypothesized mean. |
Power curve | Ticked by default: draws power against sample size. |
Title | Title shown on the output and the power curve. |

Figure 1 — Solving for power: Sample sizes = 10 20 30, Differences = 1.5, Known standard deviation = 2.5, two-sided at 95% confidence.
Output Descriptions
- Settings — what was solved for, the known standard deviation, the confidence level and the alternative hypothesis.
- Results — one row per combination: difference, sample size, and power when solving for power, target and actual power when solving for sample size, or difference when solving for difference.
- Power Curve — power against sample size for each difference, with the calculated points marked.
- PDF export via Download.

Figure 2 — Results for the example: power 0.475, 0.765 and 0.908 for 10, 20 and 30 packs at a 1.5 g shift.
Worked Example
A food packer audits the mean weight of 250 g packs. Years of stable control-chart data put the standard deviation at 2.5 g, so it is treated as known. A shift of 1.5 g in either direction would matter, and the audit team wants to compare samples of 10, 20 and 30 packs. They enter Sample sizes = 10 20 30, Differences = 1.5 and Known standard deviation = 2.5, leave Power values blank, and keep the two-sided alternative at 95% confidence.
The power is 0.475 with 10 packs, 0.765 with 20 and 0.908 with 30. A 10-pack audit would miss a real 1.5 g shift more than half the time, so the team moves to 30 packs; solving for sample size with Power values = 0.9 confirms that 30 packs are the minimum for 90% power. With 20 packs and 80% power the smallest shift detectable is 1.57 g. Had the standard deviation been estimated from each sample (the 1-Sample t calculation), the powers would be lower: 0.396, 0.721 and 0.888.
Frequently asked questions
When should you use the 1-sample Z power calculation instead of 1-sample t?
Use the Z calculation only when the process standard deviation really is known and stable, for example from years of control chart data. If the standard deviation will be estimated from the sample, use Power and Sample Size for 1-Sample t. Because the standard deviation is not estimated, Z gives slightly higher power than t at the same sample size, most noticeably for small samples.
What is the sample size formula for a 1-sample Z-test?
The sample size for a target power is n = ((z + z_beta) / d) squared, where d is the difference divided by the known standard deviation, z is the critical value for the chosen alternative and z_beta is the normal quantile of the target power. The result is rounded up and the power at that whole number is reported as the actual power.
How do you find the smallest detectable difference?
For a given sample size and power, the smallest detectable difference is the standard deviation times (z + z_beta) divided by the square root of n. It is reported as a negative difference for the less-than alternative. In a worked example with a known standard deviation of 2.5 g, 20 packs at 80% power can detect a shift of 1.57 g.
How does sample size change the power of a 1-sample Z-test?
Power rises with sample size. In a worked example with a known standard deviation of 2.5 g and a 1.5 g shift, two-sided at 95% confidence, power is 0.475 with 10 packs, 0.765 with 20 and 0.908 with 30. Estimating the standard deviation instead, as in the 1-Sample t calculation, would give lower powers of 0.396, 0.721 and 0.888.